Representations on Deposit Joint Local Development Plan - POLICY CYF1, C6 - Adwy'r Hafan, Pwllheli

Representation ID: 1620

SUPPORT Dwr Cymru Welsh Water (Mr Dewi Griffiths )

Summary:

* Pwllheli Wastewater Treatment Works (WwTW) can accommodate the foul flows from the domestic demands arising from this development area

Representation ID: 1619

SUPPORT Dwr Cymru Welsh Water (Mr Dewi Griffiths )

Summary:

* Our local water network is sufficient to provide the domestic water demands required to serve this development area.
* A sewage pumping station (SPS) is located within the site and an assessment may be required to establish whether the flows from this site can be accommodated or whether future improvements to the SPS will be required to allow development to proceed. Should the existing sewerage infrastructure not be sufficient to accommodate the proposed level of growth the provision of sewerage infrastructure can be acquired through the sewer requisition provisions of the Water Industry Act 1991 (as amended).

Representation ID: 1082

OBJECT Cyfoeth Naturiol Cymru / Natural Resource Wales (Ymgynhoriadau Cynllunio

Summary:

The land is located within flood zone C1 of the Welsh Government's TAN15: Development Advice Maps. Developing this land for employment use would contradict national policy guidance contained within TAN15. NRW considers that the flood risk associated with this site has not been adequately assessed.
NRW recommends that either a stage 2 or stage 3 SFCA is prepared and forwarded to NRW for further assessment to demonstrate that developing this site for employment use would comply with the requirements of TAN15 or that development brought forward under this allocation includes no erection of new employment units within the site.

Representation ID: 105

OBJECT Natural Resources Wales (Mr Gareth Thomas)

Summary:

Site C6 is within flood zone C1 of Welsh Government's TAN15: Development Advice Maps. The flood risk has not been assessed. Locating a new employment unit within the site would contradict national policy TAN15. The SFCA, section 9.3 states that none of the allocations fall within zones C1 or C2. There may be risk of flooding due to a breach of the defences (sand dunes)along the eastern boundary, and the potential for flood water to enter the site from over the quay wall to the west of the site.

Either a stage 2/stage 3 SFCA submitted that demonstrates the site would comply with TAN15 requirements, or that no NEW employment units to be provided within this site.